The limits of allowable relative error of the pressure measuring channel in the unconverted range of
the pressure measurement and at an ambient temperature of -40 to +60 °С, not more than |
±0,4% |
The limits of allowable relative error of the gas temperature measuring channel at ambient temperature from -40 to +60 °С, not more than |
±0,1% |
The limits of allowable relative error of convertion of the measured gas volume to standard conditions in accordance with GOST 2939 in
the unconverted range of the pressure measurement and at an ambient temperature of -40 to +60 °С, not more than |
±0,5% |
The limits of allowable relative error in calculation of the volume of gas converted to standard conditions, not more than |
±0,05% |
The limits of allowable converted error of the differential pressure measuring channel in the unconverted range of the pressure
drop and at ambient temperature from -40 to +60 °С, no more than |
±0,25% |
The limits of the allowable absolute error of the ambient temperature measuring channel at an ambient temperature from -40 to +60 °С, no more than |
±1 °С |
Note. The requirement for error in computation is ensured by the applied computational algorithms and high-precision electronic computational components.